list of publication


back

1 T.Yambe, S.Nitta, Y.Katahira, M.Tanaka, N.Satoh, M.Miura, H.Mohri, M.Yoshizawa, & H.Takeda: Effect of left ventricular assistance on sympathetic tone. Int J Artif Organs 13: 681- 686, 1990.
2 T.Yambe, S.Nitta, Y.Katahira, T.Sonobe, S.Naganuma, H.Akiho, H.Hayashi, M.Tanaka, M.Miura, N.Satoh, H.Mohri, M.Yoshizawa, and H.Takeda: Postganglionic sympathetic activity with correlation to heart rhythm during left ventricular assistance. Artif Organs 15: 212-217, 1991.
3 T.Yambe, S.Nitta, S.Chiba, Y.Saijoh, S.Naganuma, H.Akiho, Y.Kakinuma, M.Tanaka, T.Meguro, K.Nitta, N.Endoh, Y.Katahira, H.Takeda, K.Takahashi, T.Sonobe: Silent Obstruction of the coronary stenosis between diagnostic angiography and percutaneous transluminal coronary angioplasty without myocardial infarction. Tohoku J Exp Med 163: 167-174, 1991.
4 T.Yambe, S.Nitta, Y.Katahira, T.Sonobe, S.Naganuma, H.Akiho, H.Hayashi, M.Tanaka, M.Miura, N.Satoh, H.Mohri, M.Yoshizawa, and H.Takeda: The prospective control of a total artificial heart using sympathetic tone and hemodynamic parameters. In: T.Akutsu & H.Koyanagi eds, Artificial Heart 3. Tokyo: Springer-Verlag, 1991: 189-195.
5 T.Yambe, S.Nitta, Y.Katahira, T.Sonobe, S.Naganuma, H.Akiho, H.Hayashi, M.Tanaka, M.Miura, N.Satoh, H.Mohri, M.Yoshizawa, and H.Takeda: Influence of left ventricular assistance on postganglionic sympathetic activity with correlation to heart rhythm and the pumping rhythm. In: M.Yoshikawa, M.Uono, H.Tanabe, S.Ishikawa eds, New Trends in Autonomic Nervous System Research -Basic and Clinical Investigation. Amsterdam: Excerpta Medica, 1991: 364-365.
6 T.Yambe: Experimental study of renal sympathetic nerve activity during left ventricular assist device pumping" Sci Rep Res Inst Tohoku Univ-C 37: 1-9, 1991.
7 T.Yambe, S.Nitta, Y.Katahira, T.Sonobe, S.Naganuma, H.Akiho, H.Hayashi, M.Tanaka, M.Miura, N.Satoh, H.Mohri, M.Yoshizawa, and H.Takeda: Coherence function between sympathetic neurogram and arterial pulse wave in animal with total artificial heart. Sci Rep Res Inst Tohoku Univ-C 38: 35-41, 1991.
8 T.Yambe, S.Nitta, Y.Katahira, M.Tanaka, N.Satoh, M.Miura, H.Mohri, M.Yoshizawa, and H.Takeda: Effect of left ventricular assistance in the various pumping mode on sympathetic Tone. Artif. Organs 14(suppl-1): 146-148, 1991.
9 T.Yambe, S.Nitta, Y.Katahira, T.Sonobe, S.Naganuma, H.Akiho, H.Hayashi, M.Tanaka, M.Miura, N.Satoh, H.Mohri, M.Yoshizawa, and H.Takeda: Development of the total artificial heart control system. Sci Rep Res Inst Tohoku Univ-C 38: 29-34, 1991.
10 T.Yambe, S.Nitta, Y.Katahira, M.Tanaka: Spectralni analyza srdecni sympaticke aktivity pri levokomorovem podpurnem systemu. Lekar a Technika 22: 13-15, 1991.
11 T.Yambe, S.Nitta, S.Chiba, Y.Saijoh, S.Naganuma, H.Akiho, H.Hayashi, M.Tanaka, M.Miura, N.Satoh, H.Mohri, M.Yoshizawa, and H.Takeda: Cardiac related sympathetic nerve activity during circulatory maintenance with left ventricular assist device. Int J Artif Organs 15: 49-54, 1992.
12 T.Yambe, S.Nitta, Y.Katahira, T.Sonobe, S.Naganuma, H.Akiho, H.Hayashi, M.Tanaka, M.Miura, N.Satoh, H.Mohri, M.Yoshizawa, and H.Takeda: Experimental study for the prospective control of the ventricular assist device using the information of sympathetic tone and hemodynamic derivatives" In Y.Sezai ed. Artificial Heart -The development of Biomation in the 21st Century. Philadelphia: W.B. Saunders Company, 1992: 178-182.
13 T.Yambe, S.Nitta, Y.Katahira, T.Sonobe, S.Naganuma, Y.Kakinuma, H.Matsuzawa, M.Tanaka, M.Miura, N.Satoh, H.Mohri, M.Yoshizawa, and H.Takeda: Fundamental rhythm of the sympathetic nerve discharges in animals with total artificial hearts. ASAIO J 39: 91-95, 1992.
14 T.Yambe, S.Nitta, Y.Katahira, T.Sonobe, M.Tanaka, N.Satoh, M.Miura, H.Mohri, M.Yoshizawa, and H.Takeda: Optimal drive of a ventricular assist device using renal sympathetic nerve information. Artif Organs Today 2: 35-43, 1992.
15 T.Yambe, S.Nitta, Y.Katahira, T.Sonobe, S.Naganuma, Y.Kakinuma, H.Akiho, N.Satoh, M.Miura, H.Mohri, M.Yoshizawa, S.Koide, and H.Takeda: Rhythmical fluctuations of the arterial blood pressure in animals with total artificial hearts. Proceed 14th Ann Int Conf IEEE Eng in Med Biol Soc 2: 369-380, 1992.
16 T.Yambe, S.Nitta, S.Chiba, Y.Saijoh, S.Naganuma, H.Akiho, H.Hayashi, M.Tanaka, M.Miura, N.Satoh, H.Mohri, M.Yoshizawa, and H.Takeda: Estimation of the following cardiac output using sympathetic tone and hemodynamics for the control of total artificial heart. Int J Artif Organs 15: 606-610, 1992.
17 T.Yambe, S.Nitta, Y.Katahira, T.Sonobe, S.Naganuma, H.Akiho, H.Hayashi, M.Tanaka, M.Miura, N.Satoh, H.Mohri, M.Yoshizawa, and H.Takeda: New artificial heart control method from the neurophysiological point of view. In T. Akutsu & H.Koyanagi eds. Artificial Heart 4. Tokyo: Springer-Verlag, 1992: 353-356.
18 T.Yambe, S.Nitta, S.Chiba, Y.Saijoh, S.Naganuma, H.Akiho, H.Hayashi, M.Tanaka, M.Miura, N.Satoh, H.Mohri, M.Yoshizawa, and H.Takeda: Mayer waves in animals with total artificial heart. Int J Artif Organs 15: 601-605, 1992.
19 T.Yambe, S.Nitta, Y.Katahira, T.Sonobe, M.Tanaka, N.Satoh, M.Miura, H.Mohri, M.Yoshizawa, and H.Takeda: Estimation of the ventricular assist device driving condition from the neurophysiological point of view. Artif Organs Today2: 309-316, 1993.
20 T.Yambe, S.Nitta, Y.Katahira, T.Sonobe, M.Tanaka, N.Satoh, M.Miura, H.Mohri, M.Yoshizawa, and H.Takeda: Evaluation of the air driven pump chamber used in the ventricular assist device by hydrodynamic analysis of the prosthetic valve. Artif Organs Today 2: 279-285, 1993.
21 T.Yambe, S.Nitta, S.Chiba, Y.Saijoh, S.Naganuma, Y.Kakinuma, M.Tanaka, T.Meguro, N.Endoh, M.Mitsuoka, T.Naganuma, T.Ohtomo, Y.Terasawa, K.Nitta, Y.Katahira, T.Sonobe, H.Takeda, and K.Takahashi: Long time inflation of the PTCA balloon. Sci Rep Res Inst Tohoku Univ-C 38: 75-82, 1992.
22 T.Yambe, S.Nitta, Y.Katahira, T.Sonobe, S.Naganuma, Y.Kakinuma, M.Tanaka, T.Fukuju, M.Miura, H.Mohri, M.Yoshizawa, S.Koide, H.Takeda, H.Hiyama, M.Aoki, T.Kasai, and H.Hashimoto: Systemic circulation with high frequency blood flow - analysis from neurophysiological point of view. Sci Rep Res Inst Tohoku Univ-C 38: 69-74, 1992.
23 T.Yambe, S.Nitta, Y.Katahira, T.Sonobe, M.Tanaka, N.Satoh, M.Miura, H.Mohri, M.Yoshizawa, and H.Takeda: Dependance of the sympathetic outflow on biventricular assist device driving frequency. Artif Organs 17: 18-23, 1993.
24 T.Yambe, S.Nitta, Y.Katahira, T.Sonobe, M.Tanaka, N.Satoh, M.Miura, H.Mohri, M.Yoshizawa, H.Takeda, T.Kasai, and H.Hashimoto: Power spectral analysis of rhythmical fluctuations in hemodynamic parameters during prosthetic high frequency blood flow. Artif Organs Today 3: 99-106, 1993.
25 T.Yambe, S.Nitta, Y.Katahira, T.Sonobe, M.Tanaka, N.Satoh, M.Miura, H.Mohri, M.Yoshizawa, and H.Takeda: Is there any rhythmical fluctuations in hemodynamic parameters during complete prosthetic circulation with artificial heart ? Artif Organs Today 3: 93-98, 1993.
26 T.Yambe, S.Nitta, S.Chiba, Y.Saijoh, S.Naganuma, Y.Kakinuma, M.Tanaka, T.Meguro, N.Endoh, M.Mitsuoka, T.Naganuma, T.Ohtomo, Y.Terasawa, K.Nitta, Y.Katahira, T.Sonobe, H.Takeda, and K.Takahashi: Differentiation of the transiently ischemic from infarcted myocardium by thallium-201 exercise scintigram after active ergometer rehabilitation. Ann Nucl Med 7: 187-192, 1993.
27 T.Yambe, S.Nitta, T.Sonobe, S.Naganuma, Y.Kakinuma, S.Kobayashi, .Nanka, N.Ohsawa, H.Akiho, M.Tanaka, T.Fukuju, M.Miura, N.Uchida, N.Sato, H.Mohri, M.Yoshizawa, S.Koide, K.Abe, and H.Takeda: Origin of the rhythmical fluctuations in hemodynamic parameters in animal without natural heartbeat. Artif Organs: 1071-1021, 1993.
28 T.Yambe, S.Nitta, Y.Katahira, T.Sonobe, S.Naganuma, Y.Kakinuma, M.Tanaka, T.Fukuju, M.Miura, H.Mohri, M.Yoshizawa, S.Koide, and H.Takeda: Identification of the deterministic chaos in cardiovascular dynamics by the use of the non-linear mathematical analysis. Sci Rep Res Inst Tohoku Univ-C 39: 1-7, 1994.
29 T.Yambe, S.Nitta, Y.Katahira, T.Sonobe, S.Naganuma, Y.Kakinuma, M.Tanaka, T.Fukuju, M.Miura, H.Mohri, M.Yoshizawa, S.Koide, and H.Takeda: Nonlinear mathematical analysis of the hemodynamics with artificial heart. In: Y.Sezai ed. Artificial Heart 1993, Switzerland: Harwood Academic publishers, 1993: 121-122.
30 T.Yambe, S.Nitta, T.Sonobe, S.Naganuma, Y.Kakinuma, K.Izutsu, H.Akiho, S.Kobayashi, N.Ohsawa, S.Nanka, M.Tanaka, T.Fukuju, M.Miura, N.Uchida, N.Sato, K.Tabayashi, S.Koide, K.Abe, H.Takeda, and M.Yoshizawa: Deterministic chaos in the hemodynamics of an artificial heart. ASAIO Journal 41: 84-88, 1995.
31 T.Yambe, S.Nitta, T.Sonobe, S.Naganuma, Y.Kakinuma, S.Kobayashi, S.Nanka, N. Ohsawa, H.Akiho, M.Tanaka, T.Fukuju, M.Miura, N.Uchida, N.Sato, H.Mohri, M.Yoshizawa, S.Koide, K.Abe, H.Takeda: Fluctuations in sympathetic nerve activity in animal without natural heartbeat. Artif Organs 18: 775-780, 1994.
32 T.Yambe, S.Nitta, T.Sonobe, S.Naganuma, Y.Kakinuma, S.Kobayashi, S.Nanka, N.Ohsawa, H.Akiho, M.Tanaka, T.Fukuju, M.Miura, N.Uchida, N.Sato, H.Mohri, M. Yoshizawa, S.Koide, K.Abe, H.Takeda: Chaotic hemodynamics during oscillated blood Flow. Artif Organs 18: 633-637, 1994.
33 T.Yambe, S.Nitta, T.Sonobe, S.Naganuma, Y.Kakinuma, S.Kobayashi, S.Nanka, N. Ohsawa, H.Akiho, M.Tanaka, T.Fukuju, M.Miura, N.Uchida, N.Sato, H.Mohri, M. Yoshizawa, S.Koide, K.Abe, H.Takeda: Chaotic behavior of the hemodynamics with ventricular assist device. Int J Artif Organs 18: 17-21, 1995.
34 T.Yambe, S.Nitta, T.Sonobe, S.Naganuma, Y.Kakinuma, S.Kobayashi, S.Nanka, N. Ohsawa, H.Akiho, M.Tanaka, T.Fukuju, M.Miura, N.Uchida, N.Sato, H.Mohri, M.Yoshizawa, S.Koide, K.Abe, H.Takeda: Fractal dimension analysis of the oscillated blood flow with vibrating flow pump. Artif Organs 19: 729-733, 1995.
35 T.Yambe, S.Nanka, T.Sonobe, S.Naganuma, S.Kobayashi, H.Akiho, Y.Kakinuma, K.Yukita, M.Mitsuoka, S.Chiba, N.Ohsawa, Y.Haga, K.Idutsu, S.Nitta, T.Fukuju, M.Miura, N.Uchida, N.Sato, K.Tabayashi, A.Tanaka, N.Yoshizumi, K.Abe, H.Takeda, M.Takayasu, M.Yoshizawa, and H.Takayasu: Fractal dimension analysis of the chaos in hemodynamics with artificial heart. In: H.Koyanagi, T.Akutsu, eds. Heart replacement - Artificial Heart 5, Tokyo: Springer-Verlag, 1995: 317-320.
36 T.Yambe, S.Nitta, T.Sonobe, S.Naganuma, Y.Kakinuma, S.Kobayashi, S.Nanka, N. Ohsawa, H.Akiho, M.Tanaka, T.Fukuju, M.Miura, N.Uchida, N.Sato, H.Mohri, M. Yoshizawa, S.Koide, K.Abe, H.Takeda: Can the artificial heart make the circulation become fractal? Int J Artif Organs 18: 317-320, 1995.
37 T.Yambe, S.Nitta, S.Nanka, M.Yoshizawa, H.Takayasu, S.Iwase, Y.Sugiyama, T.Mano: Fractal dimension analysis of the muscle sympathetic nerve activity. Pathophysiology 2: 173 176, 1995.
38 T.Yambe, S.Nitta, S.Nanka, M.Yoshizawa, H.Takayasu, S.Iwase, Y.Sugiyama, T.Mano, K.Gouhara. Fractal analysis of the sympathetic discharges. IIAS reports 1996-01: 71-86, 1996.
39 T.Yambe, S.Nanka, S.Naganuma, S.Kobayashi, S.Nitta, T.Fukuju, N.Uchida, K.Tabayashi, A.Tanaka, K.Abe, H.Takayasu, and H.Takeda: Correlation dimension of the artificial Circulation. Artif Organs Today (in press).
40 T.Yambe, S.Nanka, S.Naganuma, S.Kobayashi, H.Akiho, Y.Kakinuma, N.Ohsawa, S.Nitta, T.Fukuju, M.Miura, N.Uchida, K.Tabayashi, A.Tanaka, N.Yoshizumi, K.Abe, M.Takayasu, H.Takayasu, M.Yoshizawa, H.Takeda, K.Gouhara. Fractal circulation of the total artificial heart. IIAS Reports 1996-01: 87-106, 1996.
41 T.Yambe, S.Nanka, S.Naganuma, S.Kobayashi, S.Nitta, T.Fukuju, N.Uchida, K.Tabayashi, A.Tanaka, K.Abe, H.Takayasu, and H.Takeda: Extraction of the 1/f fluctuation in hemodynamics of an artificial heart. Artif Organs 20: 777-782, 1996
42. T.Yambe, S.Kobayashi, S.Nanka, S.Naganuma, S.Nitta, H.Matsuki, K.Abe, M.Yoshizawa, T.Fukuju, K.Tabayashi, H.Takeda, H.Hashimoto. Spectral characteristics of the arterial blood pressure during left ventricular assistance using oscillated blood flow. IIAS Reports 1997-006, 145-156, 1997.
43 T.Yambe, S.Kobayashi, S.Nanka, S.Naganuma, S.Nitta, M.Yoshizawa, T.Fukuju, N.Uchida, and K.Tabayashi: Spectral analysis of the hemodynamics during left ventricular assistance. Int J Artif Organs 19: 367-371, 1996
44. T.Yambe, S.Kobayashi, S.Nanka, S.Naganuma, S.Nitta, M.Yoshizawa, T.Fukuju, N.Uchida, and K.Tabayashi: Pneumatically driven ventricular assist device and heart rate variability. IIAS Reports 1997-006, 187-168, 1997.
45 T.Yambe, S.Kobayashi, S.Nanka,S.Naganuma,S.Nitta, H.Matsuki, M.Yoshizawa, H.Hashimoto: Fluctuations of the hemodynamic derivatives during left ventricular assistance using oscillated blood flow. Artif Organs 20: 637-640, 1996
46 T.Yambe, Y.Abe, M.Yoshizawa, K.Imachi, K.Tabayashi, H.Takayasu, H.Takeda, K. Gouhara, S.Nitta: Strange hemodynamic attractor parameter with 1/R total artificial heart automatic controlalgorithm. Int J Artif Organs 19: 302-306, 1996.
47. T.Yambe, S.Nanka, T.Sonobe, S.Naganuma, S.Kobayashi, K.Shizuka, M.Watanabe, A.Tanaka, M.Yoshizawa, K.Abe, M.Miura, K.Tabayashi, H.Takayasu, K.Gouhara, K.Naitoh, H.Takeda, S.Nitta: Sympathetic nerve adjustment to artificial circulation. In: H.Koyanagi, T.Akutsu, eds. Heart replacement - Artificial Heart 6, Tokyo: Springer-Verlag, 1998, pp.308-312
48 T.Yambe, K.Shizuka, K.Izutsu, T.Sonobe, S.Naganuma, S.Kobayashi, S.Nanka, H. Hashimoto, M.Yoshizawa, K.Tabayashi, H.Takeda, S.Nitta: Pulmonary arterial impedance analysis by the use of the oscillated flow. Artif Organs 21: 751-754, 1997.
49. T.Yambe, K.Gouhara, K.Naitoh, S.Nitta: Nonlinear dynamical behavior of sympathetic nerve attractors with total artificial heart. IIAS reports1997-006, 183-188, 1997.
50 T.Yambe, S.Kobayashi, T.Sonobe, S.Naganuma, S.Nanka, H.Hashimoto, M.Yoshizawa, K.Tabayashi, H.Takayasu, H.Takeda, S.Nitta: Nonlinear mathematical analysis of the hemodynamic parameters during left ventricular assistance with oscillated blood flow. Artif Organs 21: 625-629, 1997
51 T.Yambe, S.Nanka, K.Shizuka, T.Sonobe, M.Yoshizawa, S.Nasukawa, S.Nitta: Development of the virtual PTCA system. Proceed for ICAT96; 105-113, 1996
52 T.Yambe, M.Yoshizawa, S.Nanka, Y.Sugiyama, T.Mano, H.Takayasu, H.Takeda, S.Nitta: Responses of the autonomic nervous system to the virtual reality immersion. Proceed for VSMM96 in Gifu: 274-277, 1996.
53 T.Yambe, M.Yoshizawa, M.Yoshizumi, S.Nanka, T.Sonobe, H.Takayasu,K.Gouhara, H.Takeda, K.Abe, S.Nitta: Reconstruction of the chaos attractor of the left ventricular wall motion in the patients with myocardial infarction. Proceed for second IMIA/IFMBEWorkshop on Biosignal Interpretation: 111-114, 1996
54 T.Yambe, Abe Y, Yoshizawa M, Imachi K, Tabayashi K, Takayasu H, Takeda H, Gouhara K, Nitta S: Lyapunov exponents of hemodynamic derivatives with 1/R total artificial heart automatic control algorithm. IIAS reports 1997-006: 169-181, 1997.
55 T.Yambe, H.Hashimoto, S.Kobayashi, T.Sonobe, S.Naganuma, S.Nanka, H.Matsuki, M.Yoshizawa, K.Tabayashi, H.Takayasu, H.Takeda, S.Nitta: Development and evaluation of totally implantable ventricular assist system using a vibrating flow pump and transcutaneous energy transmission system with amorphous fibers. Heart and vessels 12(suppl-12): 86-88, 1997
56. T.Yambe, M.Yoshizawa, S.Nitta: Educational support system for the interventional specialist by the use of the technology of virtual reality. IIAS reports 1998-002: 11-15, 1998.
57. T.Yambe, N.Owada, S.Kobayashi, T.Sonobe, S.Naganuma, S.Nanka, H.Hashimoto, M.Yoshizawa, K.Tabayashi, H.Takayasu, H.Takeda, S.Nitta: Apical apploaches of the left ventricular assist device using vibrating flow pump. IIAS reports 1998-002: 17-20, 1998.
58. T.Yambe, H.Hashimoto, M.Yoshizawa, A.Tanaka, K.Abe, T.Fukuju, M.Miura, K.Tabayashi, H.Takeda, K.Izutsu, T.Sonobe, S.Naganuma, S.Kobayashi, S.Nanka, S.Nitta: New therapeutic methodology for the patients with pulmonary hypertension. IIAS reports 1998-002: 21-25, 1998.
59. T.Yambe, Y.Abe, K.Imachi, S.Nanka, A.Tanaka, M.Yoshizawa, K.Tabayashi, H.Takeda, S.Nitta: Development of the artificial baroreflex system. IIAS reports 1998-002: 27-31, 1998.
60 T.Yambe, S.Kobayashi, S.Nanka, M.Yoshizawa, K.Tabayashi, H.Takeda, S.Nitta: Monitoring system for the totally implantable artificial heart using virtual reality. Int J Artif Organs 21: 348-352, 1998.
61. T.Yambe, N.Tanizuka, A.Tanaka, M.Yoshizawa, S.Nitta: Prospective control of an artificial heart system. IIAS reports 1998-007: 135-140 1998.
62. T.Yambe, S.Kobayashi, H.Hashimoto, M.Yoshizawa, H.Mastuki, K.Tabayashi, H.Takeda, S.Nitta: Chaos in circulation with vibrating flow type artificial heart system. IIAS report 1998-007: 97-102 1998.
63. T.Yambe, A.Tanaka, M.Yoshizawa, S.Nitta: Mayer wave control for a total artificial heart. IIAS report 1998-007: 103-108, 1998.
64. T.Yambe, M.Yoshizawa, M.Osaka, S.Nitta: Origin of chaos in circulation. IIAS report 1998-007: 79-92, 1998.
65. T.Yambe, S.Nanka, S.Kobayashi, A.Tanaka, M.Yoshizawa, K.Tabayashi, H.Takeda, T.Nishihira, S.Nitta: Effect of ACE inhibitor upon nonlinear dynamics in hemodynamic parameters. IIAS report 1998-007: 109-112, 1998.
66 T.Yambe, M.Yoshizawa, M.Osaka, S.Nitta: Origin of chaos in circulation. IIAS report 1998-007: 79-92, 1998.
67 T.Yambe, A.Fukutome, S.Kobayashi, S.Nanka, M.Yoshizawa, H.Takeda, S.Nitta,: Development of total artificial heart having advantages in economy and durability. Int J Artif Organs 21: 279-284, 1998.
68 T.Yambe, N.Owada, S.Kobayashi, T.Sonobe, S.Naganuma, S.Nanka, H.Hashimoto, H.Matsuki, M.Yoshizawa, K.Tabayashi, H.Takayasu, H.Takeda, S.Nitta: Left heart bypass using the oscillated assist flow with totally implantable vibrating flow pump. Artif Organs 22: 426-429, 1998.
69 T.Yambe, K.Izutsu, H.Hashimoto, M.Yoshizawa, A.Tanaka, K.Abe, T.Fukuju, M.Miura, K.Tabayashi, H.Takeda, K.Shizuka, T.Sonobe, S.Naganuma, S.Kobayashi, S.Nanka, S.Nitta: Control of pulmonary arterial resistance by the use of the oscillated assist flow. Artif Organs 22: 430-433, 1998.
70 T.Yambe, M.Yoshizawa, K.Tabayashi, H.Takeda, S.Nitta: Virtual percutaneous transluminal coronary angioplasty system for the educational support system. Artif Organs 22: 710-713, 1998.
71. T.Yambe, M.Yoshizawa, K.Tabayashi, S.Nitta: Searching for the origin of chaos. In: M.Akay ed. Nonlinear Biomedical Signal Processing, IEEE EMBS book series pp 40-72. 2001
72. T.Yambe, T.Nomura, S.Nanka, S.Kobayashi, A.Tanaka, M.Yoshizawa, K.Abe, K.Tabayashi, H.Takeda, S.Nitta: Continuous monitoring of the autonomic nerve information for the control of an artificial heart - Mayer wave control for TAH. ASAIO Journal: M696-699, 1998.
73 T.Yambe, S.Nanka, S.Kobayashi, A.Tanaka, M.Yoshizawa, K.Abe, K.Tabayashi, H.Takeda, S.Nitta: Origin of chaos in circulation- open loop analysis with an artificial heart. ASAIOJournal : M700-703, 1998.
74. T.Yambe, S.Nanka, A.Tanaka, M.Yoshizawa, K.Tabayashi, H.Takeda, T.Nishihira, S.Nitta: Evaluation of cardiac function by the nonlinear mathematics. IIAS reports 1998-007: 141-144, 1998
75 T.Yambe, N.Tanizuka, A.Tanaka, M.Yoshizawa, K.Abe, H.Takeda, K.Tabayashi, S.Nitta: A future prediction type artificial heart system. Artif Organs 23: 268-273, 1999.
76 T.Yambe, S.Nanka, M.Yoshizawa, K.Abe, K.Tabayashi, H.Takeda, S.Nitta: Parasympathetic nerve activity in the awake condition for the control of an artificial heart system. IIAS reports 1998-7: 93-96, 1998
77 T.Yambe, M.Yoshizawa, K.Abe, A.Tanaka, H.Takeda, S.Nitta: Making chaos with an artificial heart system. Proceed for 20th Conferences IEEE EMBS: 1561-1564, 1998. (in CD ROM)
78 T.Yambe,S.Nanka, S.Kobayashi, A.Tanaka, N.Owada, M.Yoshizawa, K.Abe, K.Tabayashi, H.Takeda, S.Nitta: Detection of cardiac function by the fractal dimension analysis. Artif Organs 23: 751-756, 1999
79 T.Yambe, S.Kawano, S.Nanka, S.Kobayashi, A.Tanaka, N.Owada, M.Yoshizawa, K.Abe, K.Tabayashi, H.Takeda, T.Nishihira, S.Nitta: Peripheral vascular resistances during total left heart bypass with an oscillated blood flow. Artif Organs 23: 747-750 , 1999
80 T.Yambe,S.Nanka, S.Kobayashi, A.Tanaka, N.Owada, M.Yoshizawa, K.Abe, K.Tabayashi, H.Takeda, S.Nitta: Vagal nerve activity in the awake condition for the control of an artificial heart system. Artif Organs 22: 529-533, 1999
81. T.Yambe, N.Owada, A.Tanaka, S.Kobayashi, S.Nanka, T.Fukuju, K.Tabayashi, M.Yoshizawa, H.Hashimoto, S.Nitta: Totally implantable ventricular assist system which can increase the brain blood flow. Artif Organs 23: 644-647, 2000.
82. T.Yambe, S.Nanka, S.Kobayashi, K.Shizuka, A.Tanaka, M.Yoshizawa, K.Abe, M.Miura, K.Tabayashi, H.Takeda, S.Nitta: Smallest ventricular assist system by the use of the peltier elements with the shape memory alloy. In: H.Koyanagi, T.Akutsu, eds. Heart replacement - Artificial Heart 7, Tokyo: Springer-Verlag, 2001, pp403-407.
83. T.Yambe, S.Kobayashi, S.Nanka, QWang, H.Hashimoto, M.Yoshizawa, K.Tbayashi, H.Takeda, S.Nitta: Autonomic nerve function during left ventricular assistance with totally implantable vibrating flow type ventricular assist device Artif Organs ( in press )
84. T.Yambe, S.Nanka, A Tanaka, M.Yoshizawa, K.Abe, K.Tabayashi, H.Takeda, S.Nitta: Evaluation of the cardiac function by chaos theory. Artif Organs ( in presss)
85. T.Yambe, A Tanaka, S.Kobayashi, Qing XL, M.Yoshizawa, K.Abe, K.Tabayashi, H.Takeda, S.Nitta: Arterialinput impedance pattern over 10 Hz. Artif Organs ( in presss)
86. T.Yambe, S.Nanka, S.Kobayashi, A.Tanaka, M.Yoshizawa, K.Abe, K.Tabayashi, H.Takeda, S.Nitta: Recording of the vagal nerve activity for the control of an artificial heart system. Artif Organs ( in press )
87. T.Yambe, N.Owada, S.Kobayashi, S.Nanka, A.Tanaka, M.Yoshizawa, K.Abe, K.Tabayashi, H.Takeda, H.Hashimoto, S.Nitta: Treatment of the multiple oregam failure by the use of the totally implantable ventricular assist device. J Artif Organs 4: 252-256, 2001
88. T.Yambe, S.Amae, S.Maruyama, Y.Luo, H.Takagi, S.Nanka, A.Tanaka, N.Kamiyama, R.Ohi, K.Tabayashi, H.Takeda, M.Yamada, S.Nitta: Application of the shape memory alloy for an internal artificial Organs. J Artif Organs ( in press )
89. T.Yambe, S.Nanka, A.Tanaka, H.Hashimoto, M.Yoshizawa, K.Tabayashi, H.Takeda, S.Nitta: Autonomic nerve function with an artificial heart and ventricular assist device. J Artif Organs 4; 83-87, 2001.
90. T.Yambe, M.Yoshizawa, K.Tabayashi, S.Nita: Searching for the origin of chaos. In: M.Akay,, ed. Noninear biomedical signal processing. Volume 2, Dynamic analysis and modeling, New York: IEEE press, 2000, pp.40-71
91. T.Yambe, S.Nanka, S.Kobayashi, K.Shizuka, A.Tanaka, M.Yoshizawa, K.Abe, M.Miura, K.Tabayashi, H.Takeda, S.Nitta: Pathological aspect of an implantable ventricular assist device with short stroke and high frequency. In: H.Koyanagi, T.Akutsu, eds. Heart replacement - Artificial Heart 7, Tokyo: Springer-Verlag, 2001, pp259-264
92. T.Yambe, M.Yoshizawa, R.Taira, A.Tanaka, K.Tabayashi, S.Nitta: Nonlinear analysis of fluctuations in E max Artif Organs 2001 (in press)
93. T.Yambe, S.Kobayashi, M.Yoshizawa, A.Tanaka, H.Mastuki, F.Sato, K.Tabayashi, S.Nitta: Recent progress of the Vibrating flow pump for totally implantable ventricular assist device Artif Organs 25; 688-691, 2001
94. T.Yambe, M.Yoshizawa, R.Taira, A..Tanaka, K.Tabayashi,:Nonlinear Analysis Of The Fluctuations In Emax Of The Left Ventricle. Artif Organs 2001 (in press)
95. T.Yambe, S.Maruyama, S.Amae, K.Nishi, M.Wada, T.Kamiyama, T.Takagi, Y.Luo, J.Hayashi, H.Matsuki, M.Yoshizawa, K.Abe, K.Tabayashi, H.Takeda, S.Nitta: Application of shape memory alloy for the artificial internal organs. J Artif Organs 2002 (in press)
96. T.Yambe, S.Kawano, S.Kobayashi, M.Yoshizawa, A..Tanaka, H.Matsuki, F.Sato, K.Tabayashi, S.Nitta,: VIBRATING FLOW PUMP- Small size implantable ventricular assist device and its pathophysiological aspects. Artif Organs 2001 (in press)
97. T.Yambe, M.Yoshizawa, A.Tanaka, K.Abem S.Kawano, H.Matsuki, S.Maruyama, S.Amae, M.Wada, T.Kamiyama, T.Takagi, Y.Luo, J.Hayashi, S.Nanka, Y.Saijo, Y.Mibiki, M.Shibata, S.Nitta: Progress in the artificial organ research in Tohoku University. Proceed 3rd Japan-Auttralia Cardiovas Bioeng Symposium. ed by M.Umetsu, NK Int Co, 2001.
98. T.Yambe, S.Maruyama, S.Amae, K.Nishi, M.Wada, T.Kamiyama, T.Takagi, Y.Luo, J.Hayashi, H.Matsuki, M.Yoshizawa, K.Abe, K.Tabayashi, H.Takeda, T.Hongo, Y.Kagawa, N.Sato, S.Nitta: Aiming at the intelligent artificial myocardium Artif Organs 2002 (in press)
99. T.Yambe, X,Duan, S,Nanka, M.Shibata, K.Tabayashi, R.Kawashima, M.Sugiura, H.Fukuda, M.Yoshizawa, A.Tanaka, K.Abe: Effect of homodynamic parameters and oxygen metabolism to the virtual reality immersion with healing video contents. Proceed 3rd Japan-Auttralia Cardiovas Bioeng Symposium. ed by M.Umetsu, pp 44-45, NK Int Co, 2001.
100. T.Yambe, Y.Abe, T.Isoyama, K.Tabayashi, S.Nanka, K.Imachi, S.Nitta: Nonlinear Dynamical Analysis Of The Hemodynamic Parameters With AnUndulation Type Artificial Heart System . Artif Organs 2001 (in press)
101. T.Yambe, M.Yoshizawa, R.Taira, A.Tanaka, K.Tabayashi, S.Tobita, S.Nitta: Fluctuations of Emax of the left ventricle: effect of atrial natriuretic polypeptide. Biomed Pharmacother 55: 1-6, 2001. S. Nitta, Y.Katahira,
102. T.Yambe, M.Tanaka, Y.Kagawa, T.Hongo, N.Sato & M..Miura. Experimental and clinical evaluation of a sac type ventricular assist device and drive system. In: T. Akutsu & H. Koyanagi, eds. Artificial Heart 2, Tokyo: Springer-Verlag, 1988: 131-138.


1. Y.Kagawa, S.Nitta, T.Hongo, N.Sato, T.Watanabe, N.Uchida, M.Tanaka, Y.Katahira,  T.Yambe, M.Ouchi & T.Shibazaki. Clinical experience with ventricular assist device. In: T. Akutsu & H. Koyanagi, eds. Artificial Heart 2, Tokyo: Springer-Verlag, 1988: 175-181.
2. S.Nitta, Y.Katahira, T.Yambe, T.Sonobe, H.Hayashi, M.Tanaka, N.Sato, M.Miura, H.Mohri, M.Esashi. Micro-pressure sensor for continuous monitoring of a ventricular assist device. Int J Artif Organs 13: 823-829, 1990.
4. S.Nitta, H.Hashimoto, T.Sonobe, Y.Katahira, T.Yambe, S.Naganuma, M.Tanaka, N.Sato, M.Miura, H.Mohri, H.Hiyama, H.Matsuki. The newly designed univalved artificial heart. ASAIO trans 37: M240-241, 1991.
5. S.Nitta, Y.Katahira, T.Yambe, T.Sonobe, M.Tanaka, M.Miura, N.Sato, H.Mohri,H.Hiyama, M.Aoki, H.Hashimoto. An electromagnetically driven univalve artificial heart. In: T.Akutsu & H.Koyanagi, eds. Artificial Heart 3, Tokyo: Springer-Verlag, 1991: 87-92.
6. Y.Katahira, S.Nitta, T.Yambe, T.Sonobe, M.Tanaka, M.Miura, N.Sato, H.Mohri, T.Nagase, R.Yoda. In vitro and in vivo evaluation of a newly designed ball valve for a ventricular assist device. Artif Organs 14(suppl-4): 34-36, 1991.
7. S.Nitta, T.Yambe, Y.Katahira, M.Tanaka, M.Yoshizawa, H. Takeda. Detection of the renal sympathetic nerve activity during an artificial heart pumping. Biotelemetry XI: 291-295, 1991.
8. S.Nitta, T.Yambe, Y.Katahira, T.Sonobe, S.Naganuma, H.Matsuzawa, H.Akiho, H.Hayashi, M.Tanaka, M.Miura, N.Sato, H.Mohri, M.Yoshizawa, H.Takeda. Spctral analysis of the renal sympathetic neurogram during left ventricular assistance. Sci Rep Res Inst Tohoku Univ C 38: 1-4, 1991.
9. S.Nitta, T.Yambe, Y.Katahira, T.Sonobe, S.Naganuma, H.Akiho, S.Chiba, Y.Kakinuma, H.Matsuzawa, H.Hayashi, K.Izutsu, Y.Kikuchi, T.Naganuma, S.Sugawara, M.Tanaka, M.Miura, N.Sato, H.Mohri, M.Yoshizawa, H.Takeda. TH-7B pneumatically driven sac type ventricular assist device and drive system. Sci Rep Res Inst Tohoku Univ-C 38: 19-27, 1991.
10. S.Nitta, T.Yambe, Y.Katahira, T.Sonobe, S.Naganuma, H.Akiho, S.Chiba, Y.Kakinuma, H.Matsuzawa, H.Hayashi, K.Izutsu, Y.Kikuchi, T.Naganuma, S.Sugawara, M.Tanaka, M.Miura, N.Sato, H.Mohri, M.Yoshizawa, H.Takeda. Sympathetic nerve activity during maintaing circulation with only left ventricular assist system. Sci Rep Res Inst Tohoku Univ-C 38: 51-56, 1992.
11. S.Nitta, T.Yambe, Y.Katahira, T.Sonobe, Y.Saijoh, S.Naganuma, H.Akiho, Y.Kakinuma, M.Tanaka, M.Miura, N.Sato, H.Mohri, M.Yoshizawa, H.Takeda, T.Nagase, A.Fukutome, R.Yota. Hydrodynamic endurance test of the prosthetic valve used in the various types of the ventricular assist devices. Sci Rep Res Inst Tohoku Univ-C 38: 57-62, 1992.
12. M.Yoshizawa, H.Takeda, M.Miura, T.Yambe, S.Nitta: An automatic monitoring and estimation tool for the cardiovascular system under ventricular assistance using fazzy logic. Proceed 2nd Int Conf Fuzzy logic and Neural Network: 1013-1016, 1992
13. S.Nitta, T.Yambe, Y.Katahira, T.Sonobe, S.Naganuma, S.Chiba, Y.Kakinuma, M.Tanaka,
M.Miura, N.Sato, H.Mohri, M.Yoshizawa, H.Takeda, I.Tamaki, K.Tamamura, M.Kusakabe. Development and clinical evaluation of the long time digital Holter ECG system using non tracking technology. Sci Rep Res Inst Tohoku Univ-C 38: 63-64, 1992.
14. S.Nitta, T.Yambe, K.Nitta, Y.Katahira, Y.Saijoh, T.Sonobe, S.Naganuma, Y.Kakinuma, M.Tanaka, M.Miura, N.Sato, H.Mohri. Echo-guided transaortic left ventricular myotomy for idiopathic hypertrophic subaortic stenosis. Sci Rep Res Inst Tohoku Univ-C 38: 65-57, 1992.
15. M.Yoshizawa, H.Takeda, H.Watanabe, T.Miura, T.Yambe, Y.Katahira, S.Nitta. An automatic control algorithm for the optimal driving of the ventricular assist device. IEEE trans on Biomed Eng 39: 243-252, 1992.
16. M.Yoshizawa, H.Hashiya, H.Takeda, K.Abe, T.Yambe, S.Nitta: Simulation study on a control strategy of total artificial heart based on vascular conductance. Proceed 15th Ann Int Conf IEEE/EMBS, 1993
17. S.Nitta, T.Yambe, T.Sonobe, S.Naganuma, Y.Kakinuma, S.Kobayashi, M.Tanaka, M. Miura, H.Mohri, H.Hashimoto, T.Maekawa, M.Uchiyama. Minimization of hemolysis in the design implovement of a totally implantable univalves artificial heart. In: T.Akustu & H.Koyanagi, ed, Heart Replacement - Artificial Heart 4, Tokyo: Springer-Verlag, 1993: 147-149.
18. M.Yoshizawa, H.Hashiya, H.Takeda, T.Yambe, S.Nitta. Simulation study on 1/R control Strategy of the artificial heart. In Y.Sezai ed, Artificial Heart 1993, Switzerland: Harwood Academic Publishers, 1993: 123-127.
19. M.Yamamoto, M.Nakao, Y.Mizutani, H.Takahashi, H.Arai, Y. Nakamura, Y.Norimatsu, N. Ikuta, R. Ando, S.Nitta, T.Yambe. Robustness of 1/f fluctuation in p-p intervals of cat's Electrocardiogram. AIP conf proceed 285: 687-692, 1993.
20. S.Nitta, T.Yambe, M.Tanaka, H.Mohri: Ventricular assist device. Asian Med J 36: 609-612, 1993.
21. M.Yoshizawa, H.Takeda, M.Miura, T.Yambe, Y.Katahira, S.Nitta. Real-time cardiac output estimation of the circulatory system under left ventricular assistance. IEEE trans Biomed Eng 40: 266-275, 1993.
22. S.Nitta, T.Yambe, M.Tanaka, H.Mohri: The total artificial heart. Asian Med J 36: 667-670, 1993.
23. M.Yoshizawa, H.Takeda, T.Yambe, S.Nitta. Assessing cardiovascular dynamics during ventricular assistance. IEEE Eng Med Biol 13: 687-692, 1994.
24. S.Nitta, T.Yambe, T.Sonobe, S.Naganuma, Y.Kakinuma, S.Kobayashi, K.Izutsu, H.Akiho, M.Tanaka, T.Kasai, H.Hashimoto. Influences of the oscillated blood flow on blood flow distribution. Artif Organs Today 4: 77-82, 1994.
25. S.Kobayashi, S.Nitta, T.Yambe, S.Naganuma, M.Tanaka, T.Kasai, H.Hashimoto. Carotid arterial impedance during oscillated blood flow. Artif Organs 18: 627-632, 1994.
26. S.Nitta, T.Yambe, T.Sonobe, S.Naganuma, S.Kobayashi, H.Akiho, M.Tanaka, T.Kasai, H.Hashimoto. Effect of arterial high-frequency generation on hemodynamic properties"In: Niimi, Oda et al. Eds. Progress in microcirculation, 1994: 459-462.
27. M.Yoshizawa, K.Abe, D.Sato, H.Takeda, T.Yambe, S.Nitta: Less-invasive estimation under cardiac assistance based on angular frequency method. Proceed 16th Ann Int Conf IEEE Eng Med Biol Soc, 1994
28. S.Nitta, T.Yambe, S.Naganuma, S.Kobayashi, H.Matsuki, M.Yoshizawa, H.Hashimoto: Tohoku university totally implantable ventricular assist system. Progress in the artificial heart, 173-180, 1995.
29 M.Yoshizawa, S.Iemura, K.Abe, H.Takeda, Y.Kakinuma, H.Akiho, T.Yambe, S.Nitta: Parameter optimization method for less-invasive and beat-by-beat estimation of Emax. Proceed 18th ann Int Conf IEEE Eng Med Biol, 1996
30. M.Yamamoto, M.Nakao, Y.Koshikawa, K.Nakamura, N.Ikuta, T.Hondou, Y.Mizutani, R.Ando, S.Nitta, T.Yambe, H.Sei. Further study on 1/f fluctuations in cat's inter-heartbeat Intervals. In: V.Bareikis & R.Katilus, eds, Noise in physical systems and 1/f fluctuations, 1995: 651-655.
31. S.Nitta, M.Yoshizawa, T.Yambe, M.Tanaka, H.Takeda. A less invasive Emax Estimation method for weaning from cardiac assistance. IEEE trans Biomed Eng 42: 1165-1173, 1995.
32. S.Nitta, T.Yambe, T.Sonobe, S.Naganuma, Y.Kakinuma, S.Kobayashi, M.Tanaka, H.Matsuki, K.Abe, M.Yoshizawa, T.Kasai, H.Hashimoto. Totally implantable ventricular assist system using vibrating flow pump. Artif Organs 19: 676-679, 1995.
33. S.Kobayashi, S.Nitta, T.Yambe, S.Naganuma, H.Hashimoto, T. Fukuju, K.Tabayashi. Experimental study of physiological advantages of assisted circulation using oscillated blood Flow. Artif Organs 19: 704-707, 1995.
34. S.Naganuma, S.Nitta, T.Yambe, S.Kobayashi, M.Tanaka, H.Hashimoto. Gas exchange efficiency of a membrane oxygenator with use of a vibrating flow pump. Artif Organs 19: 747- 749, 1995.
35. S.Kobayashi, S.Nitta, T.Yambe, T.Sonobe, S.Naganuma, H.Hashimoto: Hemolysis test of disposable type vibrating flow pump. Artif Organs (in press)
36. S.Naganuma, T.Yambe, T.Sonobe, S.Kobayashi, S.Nitta: Development of a novel centrifugal pump: magnetic rotary pump (MRP). Artif Organs (in press)
37. S.Nanka, S.Nitta, T.Yambe, T.Sonobe, S.Naganuma, S.Kobayashi, K.Tabayashi, M.Miura, M.Yoshizawa: Fractal dimension analysis of heart rate variability with left ventricular assist device. In: T.Akustu, & H. Koyanagi, eds, Heart Replacement - Artificial Heart 6, Tokyo: Springer-Verlag, 1997, pp.370-373.
38. M.Yoshizawa, S.Iemura, K.Abe, Y.Kakinuma, H.Akiho, T.Yambe, S.Nitta: Parameter optimization approach to estimation of Emax under cardiac assistance. In: T.Akustu, & H. Koyanagi, eds, Heart Replacement - Artificial Heart 6, Tokyo: Springer-Verlag, 1997, pp. 378-381
39. A.Tanaka, M.Yoshizawa, K.Abe, T.Yambe, S.Nitta: Application of adaptive pole assignment method to vascular-resistance-based control for total artificial heart. In: T.Akustu, & H. Koyanagi, eds, Heart Replacement - Artificial Heart 6, Tokyo: Springer-Verlag, 1997, pp. 424-427
40. S.Kobayashi, S.Nitta, T.Yambe, T.Sonobe, H.Hashimoto: Resonance of artery from the analysis of arterial impedance. In: T.Akustu, & H.Koyanagi, eds, Heart Replacement - Artificial Heart 6, Tokyo: Springer-Verlag, 1997
41 M.Yoshizawa, S.Iemura, K.Abe, D.Sato, H.Takeda, T.Yambe, S.Nitta: Less invasive method for estimating Emax under cardiac assistance. In: T.Akutsu, & H.Koyanagi, eds, Heart Replacement - Artificial Heart 5, Tokyo: Springer-Verlag, 1996, pp289-292
42 M.Yoshizawa, A.Tanaka, K.Abe, H.Takeda, Y.Kakinuma, H.Akiho, T.Yambe, S.Nitta: Estimation of left ventricular power. Proceed 19th Ann Conf IEEE EMBS(in CD Rom)
43 M.Yoshizawa, M.Kisanuki, K.Abe, T.Yambe, S.Nitta: Hemodynamic waveform estimation for monitoring of artificial hearts using artificial neural network. Biomedical Engineering - Applications, Basis, & Communications 8: 76-85, 1996.
44. M.Yoshizawa, K.Abe, H.Takeda, T.Yambe, S.Nitta: Classical but effective techniques for estimating cardiovascular dynamics. IEEE Eng Med Biol 16: 106-112, 1997.
45. M. Yoshizawa, A.Tanaka, K.Abe, H.Takeda, Y.Kakinuma, T.Yambe, S.Nitta: A beat-by-beat estimation method for Emax as an inverse problem. IEEE Eng Med Biol 16: 106-112, 1997.
46. M. Yoshizawa, A.Tanaka, K.Abe, H.Takeda, Y.Kakinuma, T.Yambe, S.Nitta: An approach tosingle-beat estimation of Emax as an inverse problem. Proceed 20th IEEE/EMBS: 379-382, 1998 (in CD rom
47. A.Tanaka, M.Yoshizawa, T.Nomura, K.Abe, H.Takeda, T.Yambe, S.Nitta, Y.Abe, T.Chinzei, K.Imachi: Open loop analysis of transfer characteristics from blood pressure to heart rate using effectively total artificial heart. Proceed 20th IEEE/EMBS: 454-457, 1998 (in CD rom)
48. S. Kawano, J.Yamakami, K.Kamijo, H.Hashimoto, T.Yambe, S.Nitta: Computational design of vibrating pumping device for artificial heart. In: C.R.Kleijn, S.Kawano, eds. Computational technologies for fluid thermal structural chemical systems with industrial applications. 1998, pp.52-56
49. H.Sasaki, Y.Saijo, M.Tanaka, S.Nitta, T.Yambe, Y.Terasawa: Characterization of renal angiomyolipoma by scanning acoustic microscopy. Pathology, 1998 (in press)
50. M.Osaka, T.Yambe, H.Saitoh, M.Yoshizawa, T.Ito, S.Nitta, H.Kishida, H.Hayakawa: Mutual information discloses relationship between hemodynamic variables in artificial-heart implanted dog. Am J Physiol 275: H1419-1433, 1998.
51. XZ Wang, M.Yoshizawa, A.Tanaka, K.Abe, T.Yambe, S.Nitta: Automatic detection of abnormal patterns and state identification in biological sugnals using hierarchical self-organizing map. BPES99: 461-464, 1999.
52. XZ Wang, M.Yoshizawa, A.Tanaka, K.Abe, H.Takeda, , T.Yambe, S.Nitta, K.Imachi; An automatic monitoring system for artificial hearts using self organaizing map. Proceed 1st Joint BMES/EMBS. 756 1999.
53. S. Nitta, T.Yambe: Autonomic nervous system reaction to the Virtual Reality Immersion. Proceedings of IDW99, 1043-46. 1999
54. S.Kobayashi, N.Owada, T.Yambe S.Nitta, T.Fukuju, T.Hongoh,H.Hashimoto: Total vascular resistance and blood flow frequency during left ventricular assistance using a vibrating flow pump. Artif Organs 23; 732-735, 1999
55. XZ Wang, M.Yoshizawa, A.Tanaka, K.Abe, T.Yambe, S.Nitta: An automatic monitoring system for artificial hearts based on hierarchical self-organizing map. Proceed 189 meeting of the Socoety of Instrument and control engineers.2000
56. XZ Wang, M.Yoshizawa, A.Tanaka, K.Abe, T.Yambe, S.Nitta: Automatic monitoring of an artificial heart using a double layered self-organizing map. Proceed 15th symposium on Biolog & Physiol Engineering 2000
57. M.Yoshizawa, N.Sugita, A.Tanaka, K.Abe, T.Yambe, S.Nitta: Evaluation of three dimensional Images based on cross correlation between blood pressure and heart rate. Proceed IEEE Virtual Reality 2000.
58. XZ Wang, M.Yoshizawa, A.Tanaka, K.Abe, T.Yambe, S.Nitta: An automatic monitoring system for artificial hearts by self organizing map. Proceed IEEE EMBS Asian Pacific Conference Biomed Eng
59 XZ Wang, M.Yoshizawa, A.Tanaka, K.Abe, T.Yambe, S.Nittam Y.Abe, K.Imachi: An automatic monitoring system for artificial hearts using self organizing map. ASAIO J 2000 (in press)
60 S.Nitta, T.Yambe, Y.Saijo: Artificial heart research by the use of micromachine. Proceed for Int Sympo Microomachine 2000.
61 T.Takagi, Y.Luo, S.Hara, T.Yambe, S.Amae, M.Wada, H.Nakamura: An artificial sphimcter using shape mempry alloy actuators. J Advanced Science 12; 337-342, 2000.
62 S.Nanka, T.Yambe, S.Nitta, S.Kobayashi, M.Yoshizawa, A.Tanaka: Vagal nerve activity suggest a ne control method of an artificial heart. J Congestive H Failure & Circulatory support 1; 207-212, 2001.
63 S.Kobayashi, K.Imachi, Y.Abe, T.Isoyama S.Nitta, T.Yambe: Development of the crank motor vinrating flow pump for the leftventricular assist system. J Congestive H Failure & Circulatory support 1; 351-356, 2001
64 S.Kawano, J.Yamakami, K.Kamijo, H.Hashimoto, T.Yambe, S.Nitta: Computational design of vibrating pumping device for artificial heart. PVP Vol.377-2 Computational technologies for fluid/thermal/structural/chemical systems with industrial applications vol.2. Ed by CR klein, S.Kawano, pp51-56, 2001.
65 T.Kato, S.Kawano, K.Nakanishi, H.Hashimoto, T.Yambe, S.Nitta: Computational design of VFP type artificial heart by unstructured grid. Proceed for 3rd INTERNATIONAL SYMPOSIUM ON COMPUTATIONAL TECHNOLOGIES FOR FLUID/THERMAL/CHEMICAL SYSTEMS WITH INDUSTRIAL APPLICATIONS In conjunction with the ASME PVP Division Conferenc, 2001 (in press)
66 XZ Wang, M.Yoshizawa, A.Tanaka, K.Abe, T.Yambe, S.Nitta: Automatic detection and classification of abnormalities for artificial hearts using a Hierarchical self-organizing map. Artif Organs 25; 150-153, 2001.
67 M.Yoshizawa, T.Sato, A.Tanaka, K.Abe, H.Takeda, T.Yambe, S.Nitta: A sensorless estimation of pressure head and flow of a continuous flow artificial heart. J Congestive H Failure & Circulatory support 1; 299-304, 2001
68 S.Maruyama, R.Ibuki, S.Sakai, M.Yamada, M.Sato, T.Yambe, T.Takagi, Y.Luo, M.Behnia, Development od a novel artificial heart muscle using thermoelectric actuators. Proceed 5th Congress on Experimental Heat Transfer, fkuid mechanics & Thermodynamics 2001, edts by Celeta GP, Marco PD, Goulas A, and Mariani A., pp 1207-1211.
69 XZ Wang, M.Yoshizawa, A.Tanaka, K.Abe,K.Imachi, T.Yambe, S.Nitta: An automatic monitoring system for artificial hearts using a Hierarchical self-organizing map. J Artif Organs 4; 198-204, 2001.
70 S.Kawano, J.Yamakami, K.Kamijo, H.Hashimoto, T.Yambe, S.Nitta: Computational design of vibrating pumping device for artificial heart. Journal of Pressure vessel technology 123; 525-529, 2001.
71 R.Ibuki, S.Sakai, M.Yamada, M.Sato, T.Yambe, T.Takagi, Y.Luo, M.Behnia. Development of a novel artificial heart muscle using thermoelectric actuators. Heat and Technology. 19; 75-80, 2001.
72 P.Olegario, M.Yoshizawa, A.Tanaka, K.Abe, H.Takeda, T.Yambe, S.Nitta: Prevention of left atrial wall suction in a continuous flow total artificial heart by manipulation of right pump flow rate. Proceed 41th conf JSMEB 2002